Precision Bearing

Rotary Table Bearing — Engineering Configuration V012

Exact SKU: ES-BR-C29-S001-V012

Confirm dimensions, fit, load, speed, lubrication, precision and installation conditions before final selection.

Stator outer diameter
870 mm
Limiting Speed
440 r/min
Inner Ring Diameter
650 mm
Mass
168 kg
Axial Dynamic Load Rating
358 kN
Axial Static Load Rating
2,900 kN
Bearing Height H
122 mm
Inner Ring Height H1
78 mm

Full Specifications

Grouped engineering parameters

All 15 reviewed public parameters for this exact SKU are shown below. Unreviewed source fields remain excluded.

Dimensions & Integration

Inner Ring Diameter
650 mm
Stator outer diameter
870 mm
Bearing Height H
122 mm
Inner Ring Height H1
78 mm
Dimension a
12 mm
Dimension d1
743 mm
Dimension d2
800 mm
Dimension d3
802 mm
Dimension J
680 mm
Dimension J1
830 mm

Performance Parameters

Axial Dynamic Load Rating
358 kN
Axial Static Load Rating
2,900 kN
Friction Torque
60 N·m
Limiting Speed
440 r/min

Mechanical Parameters

Mass
168 kg

Compliance

Product Integration & Compliance

OEM INTEGRATION RESPONSIBILITY

This product is a component or configurable module intended for integration into an OEM, commercial, industrial or research system.

The customer is responsible for final product selection, system-level risk assessment, safety functions, mechanical and electrical integration, validation, certification and regulatory compliance.

Published ratings apply only under the stated conditions. Confirm the operating point, interfaces, control compatibility, thermal conditions, duty cycle and required documentation before final selection.

This product is not approved for a safety-critical or restricted application unless expressly authorized in writing.

TRANSMISSION INTEGRATION

Confirm rated and peak torque, backlash, stiffness, radial and axial loads, mounting accuracy, lubrication, temperature, duty cycle, shock loading and expected service life.

Published service-life information depends on the stated load and operating assumptions and does not constitute a complete system-life guarantee.

Read Product & Service Compliance Notice